Edison Community College Allied Health Facility - Lee County Campus,
Fort Myers, Florida
Jenkins & Charland provided structural engineering services to the
architect on this two-story, 67,000 S.F. instructional and support
facility, including anatomy and physiology, cardiovascular technology,
dental hygiene, micro-biology/clinical laboratory science, nursing,
occupational therapy/physical therapy, respiratory care, and radiology
technology. A portion of the existing Gresham Hall facility was adaptively
reused for Emergency Management Services (EMS).
Key Structural Components
- Concrete frame
- Monumental stairway
- Laboratory loadings
|
Design Team Details
| Architects |
Gora/McGahey Associates in Architecture |
| Structural Engineers |
Jenkins & Charland, Inc. |
| New Construction (Total Area) |
67,000 GSF |
| Construction Cost |
$ 9.8 million |
|
Florida International University: School of Law - Miami, FL
The Fort Lauderdale office of Jenkins & Charland, Inc. is providing
structural engineering and construction administration services for
the University's new $25 million College of Law located on the University
Park Campus in Miami. The new Law School includes an auditorium, teaching
laboratories, study centers, offices and campus support services.
The project is 150,000 total gross square feet with 45% of assignable
space allocated to the Law Library. The 60- and 80-seat classrooms
are designed with tiered seating and there are also two mock courtrooms,
that include a Judge's bench equivalent in size to that in the U.S.
Supreme Court.
Key Structural Components
- Floor system is a reinforced concrete slab on precast concrete
joists
- High-strength, load bearing concrete masonry unit exterior walls
- Shallow spread footing foundation system
- Reading room is supported by long-span, composite steel wide
flange beams that float 50 feet above the auditorium below
- Auditorium walls are 35 feet high with considerable glazing,
and are constructed of a structural steel frame supporting long
span, open web, steel roof joists
|
| Owner |
Florida International University |
Design Team Details
| Architects |
Joint Venture: Harper Aiken Partners, Inc. &
Robert A.M. Stern Architects |
| Structural Engineers |
Jenkins & Charland, Inc. |
| Contractor |
Turner Construction Company |
| New Construction (Total Area) |
150,000 GSF |
| Construction Cost |
$ 25 million |
|
Seacrest Country Day School Expansion - Naples, Florida
Jenkins & Charland, Inc. provided structural engineering services
to the architect on this two-story, 17,000 S.F. addition to the existing
private school. Also included were two single-story, 4,250 S.F. administration
buildings connected by a covered walkway entrance area. The expansion
included classrooms, resource center, media/conference room and administration.
Key Structural Components
- Concrete slab-on-grade
- Load bearing masonry walls
- Concrete columns and beams
- Steel joist roof
|
Design Team Details
| Architects |
Alfred French & Associates, Inc. |
| Structural Engineers |
Jenkins & Charland, Inc. |
| New Construction (Total Area) |
21,250 GSF |
| Construction Cost |
$ 3.5 million |
|
 |
Wellington Elementary School - Palm Beach County, Florida
Jenkins & Charland provided structural engineering services for this
new $8.5 Million elementary school. The 100,000 S.F. facility has
concrete tilt-up wall panels, interior steel columns, shallow foundations;
the second floor has a concrete slab over form deck on steel joists
and girders.
|
Design Team Details
| Architect |
Fanning/Howey & Associates of Florida, Inc. |
| Structural Engineers |
Jenkins & Charland, Inc. |
| New Construction (Total Area) |
100,000 GSF |
| Construction Cost |
$ 8.5 million |
|
Seagate Elementary School Addition & Remodeling - Collier County,
Florida
Jenkins & Charland, Inc. provided structural engineering services
to the architect on this one-story, 22,500 S.F. addition to the existing
elementary school. The new construction consisted of 12 new classrooms,
physical education storage, faculty lounge, skills lab, new pay court
and exterior improvements. There was 19,000 S.F. remodeled space that
included expanding existing classrooms, administrative offices, media
center and food preparation area.
Key Structural Components
- Load bearing masonry walls
- Steel bar joist roof system
|
Design Team Details
| Architects |
Architectural Network, Inc. |
| Structural Engineers |
Jenkins & Charland, Inc. |
| New Construction (Total Area) |
22,500 GSF |
| Construction Cost |
$ 5.5 million |
|
 |
| | | | | | | |